Product Application
JZZV1-10 combined transformer is a new type of high-voltage electric energy metering device. It is composed of two fully insulated voltage transformers with the same voltage ratio to form a three-phase "V-V" connection; A and C phases are respectively connected in series with current transformers with the same current ratio. It is cast in one piece with special low-temperature epoxy resin and uses seamless silicone rubber as external insulation. This product is suitable for electric energy metering or relay protection in power lines of 10kV and below, and for assessment of power grid line losses.
Technical Parameters
● Rated Frequency: 50Hz, 60Hz
● Rated Voltage Factor: 1.9Upr 8h
● Insulation Resistance Temperature Class: Class E
● Insulation Structure: Semi-insulated
● Power Factor: cosΦ=0.8
● External Shielding Method: Metal Spraying
● Standard 2# Inner Cone
● Fuse: With replaceable fuse, size: Φ30×400mm
Technical Parameter Table
Rated Voltage Ratio (kV) | Accuracy Class Combination | Rated Output (VA) | Thermal Limit Output (VA) | Rated Insulation Level (kV) |
35/√3/0.1/√3/0.1 | 0.2/3P 0.5/3P | 50/100 120/100 | 600 | 40.5/95/200 |
35/√3/0.1/1/√3/0.1/3 | 0.2/0.5/3P | 30/50/100 | 400 | 40.5/95/200 |
35/√3/0.1/1/√3/0.1/√3/0.1/3 | 0.2/0.5/0.5/3P | 30/30/30/100 | 400 | 40.5/95/200 |
Dimensional Drawing
Keywords

Voltage transformer
Contact Us
Category
Product Application
JZZV1-10 combined transformer is a new type of high-voltage electric energy metering device. It is composed of two fully insulated voltage transformers with the same voltage ratio to form a three-phase "V-V" connection; A and C phases are respectively connected in series with current transformers with the same current ratio. It is cast in one piece with special low-temperature epoxy resin and uses seamless silicone rubber as external insulation. This product is suitable for electric energy metering or relay protection in power lines of 10kV and below, and for assessment of power grid line losses.
Technical Parameters
● Rated Frequency: 50Hz, 60Hz
● Rated Voltage Factor: 1.9Upr 8h
● Insulation Resistance Temperature Class: Class E
● Insulation Structure: Semi-insulated
● Power Factor: cosΦ=0.8
● External Shielding Method: Metal Spraying
● Standard 2# Inner Cone
● Fuse: With replaceable fuse, size: Φ30×400mm
Technical Parameter Table
Rated Voltage Ratio (kV) | Accuracy Class Combination | Rated Output (VA) | Thermal Limit Output (VA) | Rated Insulation Level (kV) |
35/√3/0.1/√3/0.1 | 0.2/3P 0.5/3P | 50/100 120/100 | 600 | 40.5/95/200 |
35/√3/0.1/1/√3/0.1/3 | 0.2/0.5/3P | 30/50/100 | 400 | 40.5/95/200 |
35/√3/0.1/1/√3/0.1/√3/0.1/3 | 0.2/0.5/0.5/3P | 30/30/30/100 | 400 | 40.5/95/200 |