Voltage Sensor
+
  • Voltage Sensor
Product Overview

This product is suitable for power systems with a rated voltage of 10kV and a rated frequency of 50Hz. It is an indoor voltage sensor with an epoxy resin insulated pillar structure. It can be used with digital instruments, microcomputer measurement and protection devices to achieve multiple functions such as line voltage measurement and zero-sequence voltage protection. Since the output of the voltage sensor is a small signal, it can be directly connected to the secondary equipment without secondary conversion. It complies with the technical specifications for the integration of primary and secondary power distribution equipment of the State Grid.

 

Implementation Standards

GB/T20840.7《Transformers Part 7: Electronic Voltage Transformers》.

 

Conditions of Use

● Ambient temperature: ﹣40℃ ~70℃, daily average temperature not exceeding 35℃; 
● No obvious dust, smoke, corrosive gases, steam or salt spray, etc.; 
● Relative humidity: Daily average not exceeding 95%, monthly average not exceeding 90%; 
● Altitude: Not exceeding 1000m (Please specify the altitude when used in plateau areas).

 

Technical Parameters

Voltage Section

ParameterValue
Rated Voltage● Phase voltage: (10kV/√3)/(6.5V/√3) 
● Zero-sequence voltage: (10kV/√3)/(13V/3)
Accuracy Class1/3P Class
Ambient Temperature Influence Variation<0.25% (-40℃~70℃ temperature range)
Insulation Resistance>1000 MΩ
Rated Load2MΩ (AC)
Operating Frequency50±2.5hz
Temperature Range-40℃~70℃
Partial Discharge (1.2um)≤20pC
Power Frequency Withstand Voltage42kV (1min)
Service Life≥15 years

 

Dimensions

Ordering Information

1) Rated voltage ratio; 
2) Accuracy class and corresponding rated load impedance; 
3) Please provide the altitude for plateau-type products; 
4) Please provide parameters such as the length of the secondary cable; 
5) For other special requirements, please consult the manufacturer.

Keywords

Voltage Sensor
+
  • Voltage Sensor

Voltage Sensor

This product is suitable for power systems with a rated voltage of 10kV and a rated frequency of 50Hz. It is an indoor voltage sensor with an epoxy resin insulated column structure. It can be used with digital instruments, computer measurement and protection devices to achieve multiple functions such as line voltage measurement and zero-sequence voltage protection. Because the voltage sensor output is a small signal, it does not require secondary conversion and can be directly connected to secondary equipment. It conforms to the State Grid's technical specifications for the integration of primary and secondary equipment in power distribution.


Product Overview

This product is suitable for power systems with a rated voltage of 10kV and a rated frequency of 50Hz. It is an indoor voltage sensor with an epoxy resin insulated pillar structure. It can be used with digital instruments, microcomputer measurement and protection devices to achieve multiple functions such as line voltage measurement and zero-sequence voltage protection. Since the output of the voltage sensor is a small signal, it can be directly connected to the secondary equipment without secondary conversion. It complies with the technical specifications for the integration of primary and secondary power distribution equipment of the State Grid.

 

Implementation Standards

GB/T20840.7《Transformers Part 7: Electronic Voltage Transformers》.

 

Conditions of Use

● Ambient temperature: ﹣40℃ ~70℃, daily average temperature not exceeding 35℃; 
● No obvious dust, smoke, corrosive gases, steam or salt spray, etc.; 
● Relative humidity: Daily average not exceeding 95%, monthly average not exceeding 90%; 
● Altitude: Not exceeding 1000m (Please specify the altitude when used in plateau areas).

 

Technical Parameters

Voltage Section

ParameterValue
Rated Voltage● Phase voltage: (10kV/√3)/(6.5V/√3) 
● Zero-sequence voltage: (10kV/√3)/(13V/3)
Accuracy Class1/3P Class
Ambient Temperature Influence Variation<0.25% (-40℃~70℃ temperature range)
Insulation Resistance>1000 MΩ
Rated Load2MΩ (AC)
Operating Frequency50±2.5hz
Temperature Range-40℃~70℃
Partial Discharge (1.2um)≤20pC
Power Frequency Withstand Voltage42kV (1min)
Service Life≥15 years

 

Dimensions

Ordering Information

1) Rated voltage ratio; 
2) Accuracy class and corresponding rated load impedance; 
3) Please provide the altitude for plateau-type products; 
4) Please provide parameters such as the length of the secondary cable; 
5) For other special requirements, please consult the manufacturer.