oil immersed transformer
+
  • oil immersed transformer
Product Application

Oil-immersed power transformer is a power transformer that uses insulating oil as cooling and insulating medium. It is widely used in power systems, industry, new energy and other fields, with good heat dissipation performance, large capacity, reliable insulation and stable operation.

 

Implementation Standards

GB 1094 GB/T 6451 IEC60076

 

Technical Parameters

● Rated high voltage: 10 (11, 10.5, 10, 6.6, 6.3, 6) kV 
● Rated low voltage: 0.4 kV 
● Connection group: Dyn11 or Yyn0 
● Frequency: 50Hz or 60Hz 
● Insulation level: LI75 AC35 / LI - AC3 
● Insulation class: F class or H class 
● Tap range: ±2×2.5% or others

ModelRated capacity (kVA)Connection groupVoltage combination High voltage (kV)Voltage combination Tap rangeVoltage combination Low voltage (kV)No-load loss (W)Load loss (W) 120℃No-load current (%)Short-circuit impedance (%)
S11-M-3030Yyn0
Dyn11
6
6.3
10
10.5
11
±5% 
±2×2.5%
0.4100630/6001.54.0
S11-M-5050130910/8701.34.0
S11-M-63631501090/10401.24.0
S11-M-80801801310/12501.24.0
S11-M-1001002001580/15001.14.0
S11-M-1251252401890/18001.14.0
S11-M-1601602802310/22001.04.0
S11-M-2002003402730/26001.04.0
S11-M-2502504003200/30500.94.0
S11-M-3153154803830/36500.94.0
S11-M-4004005704520/43000.84.0
S11-M-5005006805410/51500.84.0
S11-M-63063081062000.64.5
S11-M-80080098075000.64.5
S11-M-100010001150103000.64.5
S11-M-125012501360120000.54.5
S11-M-160016001640145000.54.5
S11-M-200020001940183000.45.0
S11-M-250025002290212000.45.0

 

 

 

Keywords

oil immersed transformer
+
  • oil immersed transformer

oil immersed transformer

Oil-immersed power transformers utilize insulating oil as a cooling and insulating medium. They are widely used in power systems, industries, and new energy sectors, featuring excellent heat dissipation, large capacity, reliable insulation, and stable operation.

Category


Product Application

Oil-immersed power transformer is a power transformer that uses insulating oil as cooling and insulating medium. It is widely used in power systems, industry, new energy and other fields, with good heat dissipation performance, large capacity, reliable insulation and stable operation.

 

Implementation Standards

GB 1094 GB/T 6451 IEC60076

 

Technical Parameters

● Rated high voltage: 10 (11, 10.5, 10, 6.6, 6.3, 6) kV 
● Rated low voltage: 0.4 kV 
● Connection group: Dyn11 or Yyn0 
● Frequency: 50Hz or 60Hz 
● Insulation level: LI75 AC35 / LI - AC3 
● Insulation class: F class or H class 
● Tap range: ±2×2.5% or others

ModelRated capacity (kVA)Connection groupVoltage combination High voltage (kV)Voltage combination Tap rangeVoltage combination Low voltage (kV)No-load loss (W)Load loss (W) 120℃No-load current (%)Short-circuit impedance (%)
S11-M-3030Yyn0
Dyn11
6
6.3
10
10.5
11
±5% 
±2×2.5%
0.4100630/6001.54.0
S11-M-5050130910/8701.34.0
S11-M-63631501090/10401.24.0
S11-M-80801801310/12501.24.0
S11-M-1001002001580/15001.14.0
S11-M-1251252401890/18001.14.0
S11-M-1601602802310/22001.04.0
S11-M-2002003402730/26001.04.0
S11-M-2502504003200/30500.94.0
S11-M-3153154803830/36500.94.0
S11-M-4004005704520/43000.84.0
S11-M-5005006805410/51500.84.0
S11-M-63063081062000.64.5
S11-M-80080098075000.64.5
S11-M-100010001150103000.64.5
S11-M-125012501360120000.54.5
S11-M-160016001640145000.54.5
S11-M-200020001940183000.45.0
S11-M-250025002290212000.45.0

 

 

 