Series air core reactor
+
  • Series air core reactor
Product Application

Dry-type hollow series reactor is a new type of reactor using new processes, new materials and new technologies. In the parallel compensation capacitor device, it is connected in series with the parallel capacitor to suppress harmonic voltage amplification, reduce system voltage waveform distortion and limit the closing inrush current when the capacitor circuit is put into operation.
The external dimensions can be customized according to user requirements.


Dimensions can be customized according to customer requirements.

 

Execution Standard

JB/T 5346-2014 GB/T 1094.6 DL 462-1992 IEC 60076-6

 

Technical Parameters

● Voltage Level: 6kV, 10kV, 20kV, 35kV, 66kV, 110kV 
● Reactance: 1-14% 
● Reactance Deviation: 0-5% 
● Impedance Unbalance Rate: No more than 2% 
● DC Resistance Unbalance Rate: No more than ±2% 
● Insulation Level: According to the corresponding voltage level or customer requirements 
● Cooling Method: Air Cooling 
● Usage Conditions: Indoor or Outdoor

 

 

Keywords

Series air core reactor
+
  • Series air core reactor

Series air core reactor

Dry-type air-core series reactors are a new type of reactor using new processes, new materials, and new technologies. In parallel capacitor compensation devices, they are connected in series with parallel capacitors to suppress harmonic voltage amplification, reduce system voltage waveform distortion, and limit the inrush current when the capacitor circuit is switched on. Dimensions can be customized according to user requirements.

Category


Product Application

Dry-type hollow series reactor is a new type of reactor using new processes, new materials and new technologies. In the parallel compensation capacitor device, it is connected in series with the parallel capacitor to suppress harmonic voltage amplification, reduce system voltage waveform distortion and limit the closing inrush current when the capacitor circuit is put into operation.
The external dimensions can be customized according to user requirements.


Dimensions can be customized according to customer requirements.

 

Execution Standard

JB/T 5346-2014 GB/T 1094.6 DL 462-1992 IEC 60076-6

 

Technical Parameters

● Voltage Level: 6kV, 10kV, 20kV, 35kV, 66kV, 110kV 
● Reactance: 1-14% 
● Reactance Deviation: 0-5% 
● Impedance Unbalance Rate: No more than 2% 
● DC Resistance Unbalance Rate: No more than ±2% 
● Insulation Level: According to the corresponding voltage level or customer requirements 
● Cooling Method: Air Cooling 
● Usage Conditions: Indoor or Outdoor

 

 

Get a Quote

Through the previous introduction, we believe you have learned enough about us and are confident to cooperate with us. Please leave your information quickly, and we will send you samples or brochures!

视频标题

Get a Quote

Through the previous introduction, we believe you have learned enough about us and are confident to cooperate with us. Please leave your information quickly, and we will send you samples or brochures!

Submit
google-site-verification: google90f4f2a4fbaac814.html